1. put the unit on the basis of the foundation, the magnetic pump between the bottom and the foundation into a pair of wedges, by adjusting the wedge, to find the level of the pump. After adjusting, tighten the anchor bolts.
2. before the installation of the pump and motor inspection, all parts should be intact, the magnetic pump should be no debris.
3. base the concrete base on the base size and bury the anchor bolt at the same time. Alcohol pump
4. the suction and spit pipes of the magnetic pump should have the support, which can not be supported by the magnetic pump. The diameter of the import and export pipeline should be unified with the inlet and outlet diameter of the pump.
The 5. is completed, and finally the magnetic pump coupling is rotated with the hand to check if there is a phenomenon of rubbing and touching, and the rotation is easy and uniform is the end of the installation.
6. the magnetic pump is strictly forbidden to extract the medium with particles and crystallizing. It is not allowed to operate continuously in the case of closing the discharge port, and the minimum flow rate should be kept.
7. magnetic pump to prevent impurities into the magnetic pump, the inlet should be set filter, the filter area should be more than 3~4 times the section of the pipeline.
8. when the viscosity of the medium is too high, the performance and power of the magnetic force pump will change, and the details are operated according to the instructions.
9. the magnetic pump must ensure that the height of the magnetic pump fits the cavitation allowance of the pump, and the loss of the pipeline and the medium should be considered.