Now we 2 bv vacuum pump on the market, the basic all adopt imported mechanical seal as standard, there are few special equipments with poor quality, in general, won't produce compression, better make sure the best within the scope of its performance efficiency. However, sometimes our equipment can also appear suddenly without vacuuming, what should we do then?
Check whether the power line is in reverse or missing, the motor turns to wrong, overhaul; Health level self-priming pump.
Check the use oil of the equipment, its oil injection should be moderate, and it should be replaced for a long time.
If the pipe is blocked or leaked from the container to the equipment, the filter element of the air filter is blocked, and the waste should be cleaned for a long time.
The system sealing degree of the suction is not satisfied, the container leakage is too large;
The blade fragmentation does not produce a vacuum and the blades need to be replaced.
In addition, our 2 bv vacuum pump in the process of operation, the bearing temperature no more than the environment temperature to 35 c, the highest temperature should not exceed 80 c, when its wear larger should be replaced in a timely manner, if they do not change in time, can also cause not vacuum phenomenon.
- Close This Page
- Recommendation: