The magnetic pump uses static seal instead of dynamic seal t

The high temperature magnetic drive pump will meet the needs of modernization of China's petro chemical plant. In order to adapt to the upgrading of energy saving equipment as soon as possible, the development of high temperature magnetic drive pump is in line with the internationally advanced products planned and manufactured according to APl610.

High temperature magnetic drive pump in the fields of petroleum, chemical, pharmaceutical, electronics, more and more manufacturers are required to process the transmission medium no leakage, high temperature environment, urgent need to select the ideal pump type, high temperature resistant magnetic absorption of the leading level of the magnetic pump production of new technology, new materials, new technology at home and abroad drive pump produced by our company, successfully solved the technical problem at present high temperature magnetic drive pump impeller components such as isolation cover, easy damage, high temperature magnetic drive pump is not high temperature, the high temperature magnetic drive pump performance is more perfect. The high temperature magnetic drive pump has been tested for a long time with continuous operation. More and more users are convinced that what they choose is the safest and most reliable pump type. We will continue to provide users with better service.

The design of high temperature magnetic drive pump has the advantages of high reliability, long service life, high level of generalization, high temperature magnetic drive pump and pump seal, high temperature magnetic force to replace the static seal seal is driven pump flow components is in a completely sealed state of the pump, as driven by magnetic coupling, the instead of the original mechanical pump mechanical seal has been ineffective solve the defects of leakage. The only leakage of the high temperature resistant magnetic drive pump is zero, because the pump has no shaft seal.

High temperature magnetic drive pump installation and use:

1, the high temperature magnetic drive pump should be installed horizontally, and it should not be erected. The high temperature magnetic drive pump body must not bear the weight of the pipeline. For the special requirements for vertical installation, the motor must be upwards.

2, when the suction surface above the pump axis, before starting the valve can open the suction pipe, if the aspiration level below the pump axis, the pipeline to be equipped with bottom valve.

3, the high temperature magnetic drive pump should be checked before the use of the motor, the motor wind blade rotation should be flexible, no clamping without abnormal sound, fasteners should be fastened.

4, check whether the rotation direction of the motor is in accordance with the steering mark of the magnetic pump.

5. After the motor is started, the discharge valve is opened slowly. After the high temperature magnetic drive pump enters the normal working state, then the discharge valve is adjusted to the required opening.

Attention to the use of high temperature magnetic drive pump:

1, due to the high temperature magnetic drive pump bearing cooling and lubrication is transported by the media, so the absolute prohibition of air to turn, while avoiding the operation of the middle road after the restart of the time and space caused by the rotation.

2, in the transmission medium, if the solid particles are contained, the inlet of the pump should be added into the filter net: if it contains ferromagnetic particles, a magnetic filter should be added.

3. The temperature of the high temperature magnetic driving pump should be less than 40 centigrade and the temperature of the motor should not exceed 75 degrees C.

4. The conveyed medium and its temperature should be within the allowable range of the pump material (see the attached table). The service temperature of high temperature magnetic drive pump is <60 degrees, the working temperature of metal pump is <100 0.2MPa, the suction pressure is less than 0.2MPa, the maximum working pressure is 1.6Mpa, the density is not greater than 1600kg/m3, the particle size is not greater than 30 &times, 10-6m2/s does not contain hard particles and fiber liquid.

5, for the medium which is easy to precipitate and crystallize, the liquid should be cleaned in time after use, and the liquid in the pump is discharged.

6. After 1500 hours of pump operation, the wear and wear of the bearing and end ring should be removed, and the unsuitable damage parts should be replaced.